A 'Device' represents the physics of the network communication or a communication device.

The 'Device' is the parent for a 'Cpu'.

Depending on the 'Line' used there are different 'Devices' possible:

ANSL

tcpip

ANSL only supports Ethernet TCP/IP communication.

Example:

from pvi import *

pviConnection = Connection() # start a Pvi connection
line = Line( pviConnection.root, 'LNANSL', CD='LNANSL')
device = Device( line, 'TCP', CD='/IF=TcpIp' )

Use ANSL Tcp/Ip communication.

ArSim

Communication with ARsim takes place via an Ethernet TCP device and with local IP address 127.0.0.1

INA2000

com<x>

Serial device. Serial communication can only be operated as a point-to-point connection (RS232 or RS422). A RS485 connection (two-wire) is not possible.

Example:

from pvi import *

pviConnection = Connection() # start a Pvi connection
line = Line( pviConnection.root, 'LNINA', CD='LNINA2')
device = Device( line, 'serial', CD='/IF=com1 /BD=57600 /PA=2' )

Use COM1 to connect with 57600 Baud and Even Parity.

tcpip

INA2000 Ethernet UDP/IP communication.

Example:

from pvi import *

pviConnection = Connection() # start a Pvi connection
line = Line( pviConnection.root, 'LNINA', CD='LNINA2')
device = Device( line, 'TCP', CD='/IF=TcpIp /SA=13' )

Use UDP/IP communication and operate with node INA number 13.

modem<x>

TAPI modem device.

Example:

from pvi import *

pviConnection = Connection() # start a Pvi connection
line = Line( pviConnection.root, 'LNINA', CD='LNINA2')
device = Device( line, 'modem', CD="/IF=modem1 /MO='ZyXEL MODEM Omni 288S' /TN='+43(7748)999'" )

Use local installed Modem as it appears in the Setup dialog box (Control Panel -> Modems) and connect to the given telephone number.

inacan<x>

CAN communication is operated as an INA2000 network with a maximum of 32 stations (can be expanded to 255). CAN node numbers are used to differentiate between individual stations.

Example:

from pvi import *

pviConnection = Connection() # start a Pvi connection
line = Line( pviConnection.root, 'LNINA', CD='LNINA2')
device = Device( line, 'inacan', CD='/IF=inacan3 /CNO=1 /SA=3' )

Use channel '1' of local installed B&R CAN Adapter as configured via the "CAN devices" menu item in the Control Panel. Act as INA node 3.

SNMP

snmp

SNMP (UDP) communication

Example:

from pvi import *

pviConnection = Connection() # start a Pvi connection
line = Line( pviConnection.root, 'LNSNMP', CD='LNSNMP')
device = Device( line, 'Device', CD='/IF=snmp /RT=2000' )

Use SNMP communication with a response timeout of 2000 ms